Automatic DB 5801 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Elektronarzędzia Automatic DB 5801. S&C Scada-Mate® Switching Systems Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 12
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Fully Integrated Package for Automation of Overhead Feeders
S&C Scada-Mate
®
Switching Systems
Outdoor Distribution, 14.4 kV through 34.5 kV
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - Switching Systems

Fully Integrated Package for Automation of Overhead FeedersS&C Scada-Mate® Switching SystemsOutdoor Distribution, 14.4 kV through 34.5 kV

Strona 2 -  Through remote

10S&C Model 5801 Automatic Switch ControlRechargeable, sealed-lead, starved-electrolyte battery packsHigh-output battery charger uses unique batte

Strona 3

11Ratings For adequate power to be available for the voltage sensors, switches must be applied on effectively grounded systems at line-to-line voltag

Strona 4

Offices Worldwide  www.sandc.com Descriptive Bulletin 768-30 July 13, 2009©Printed in U.S.A.

Strona 5

2S&C Scada-Mate Switching Systems are an innovative breakthrough for automating overhead distribution feeders. All functions necessary for such ap

Strona 6 -  (35 foot is standard)

3Featuring Scada-Mate, the industry’s leading switch . . . designed specifically for distribution automationS&C Scada-Mate Switches are integer st

Strona 7 - Switch Control Unit

4Sealed SF6 interrupters—circuit making and circuit breaking are accomplished internally with no exposed moving partsTwo S&C Current Sensors and o

Strona 8

5Two S&C Current Sensors and one S&C Current/ Voltage Sensor are included on each Scada-Mate Switch to provide three-phase monitoring of line

Strona 9

6A variety of optional features is available for Scada-Mate Switching Systems to meet your specific needs . . .Also available—25-or 45-foot shielded c

Strona 10 - Restoration System

7A complete Scada-Mate Switching System includes a control unit that provides the interface between the switch and the master-station computer or peer

Strona 11

8Self-Powered Communication and Control Unit . . . with swing-out panel openOptional auxiliary battery charger float-charges extra battery packs neede

Strona 12 - 768-30

9Externally Powered Communication and Control Unit . . . with swing-out panel openProvisions for user-specified communication deviceBattery charger/sw

Komentarze do niniejszej Instrukcji

Brak uwag